There are some limitations about the path measurement: | There are some limitations about the path measurement: | ||
# Due to technical reasons, large clock adjustments cannot be filtered out so if that happens, a very large two-way-latency is measured. Both devices does not need to be time synchronized but large adjustments shall not happen. That means that time synchronization (for example via NTP) should be enabled on both devices or disabled on both devices for best results. However, such clock adjustment miss-measurements are one-time events and will not lead to false values for the following packets. | |||
# The maximum supported packet size for the path measurement is currently 2048 bytes. Larger packets are truncated for the measurement. | |||
# NAT setups and different VLAN combinations on master and client are not supported at the moment. Such flows will be accounted as unmonitored flows in the debug view. | |||
#WAN optimizer and similar devices which rewrite some of the traffic are not supported either. If packet data is changed (like modifying the TCP header, adding TCP options, etc) the flow will account packet loss on both sides as the original packets are not seen on the other side. If the device in between also modifies the IP addresses or ports, the flows will be accounted as unmonitored. | |||
#The global setting for the packet length accounting should be set to the same value on both devices.Otherwise identical packets might be considered different because of different length and the bandwidth information will be inconsistent. | |||