1. Remote device: There are no special configuration settings necessary on the remote device. You need the following information to use | 1. Remote device: There are no special configuration settings necessary on the remote device. You need the following information to use the master device: | ||
* The IP address of the management port. | * The IP address of the management port. | ||
* The TCP port | * The TCP port on which the web site of the Multimeter is accessible (defaults to 443). | ||
* The username and password of the admin user (or any other user with admin role). | * The username and password of the admin user (or any other user with admin role). | ||
Line 48: | Line 48: | ||
'''(c)''' Click on the toggle button to enable the feature. | '''(c)''' Click on the toggle button to enable the feature. | ||
'''(d)''' | '''(d)''' Enter an descriptive name for the master device to make it easier to read the statistics. | ||
'''(e)''' For the remote device, enter the information described above. You can select a descriptive name for this device | '''(e)''' For the remote device, enter the information described above. You can select a descriptive name for this device also. | ||
'''(f)''' Enter a maximum packet delay. This parameter defines how long the master device waits for data from the remote device until it decides whether or not a packet as been lost. Larger values requires more memory. Typical values are between 2 and 5 seconds. | '''(f)''' Enter a maximum packet delay. This parameter defines how long the master device waits for data from the remote device until it decides whether or not a packet as been lost. Larger values requires more memory. Typical values are between 2 and 5 seconds. | ||
Line 56: | Line 56: | ||
'''(g)''' Finally save the configuration settings. | '''(g)''' Finally save the configuration settings. | ||
'''(h)''' At the bottom of page a note will appear in most cases that | '''(h)''' At the bottom of the page a note will appear in most cases that a restart of the packet processing is necessary. Follow the link to the administration page and click on "Restart processing". Be aware that this will interrupt the network connection for a few seconds (if in Bridge mode); you will lose all previously measured data. | ||
'''(i)''' Return to the "Generic -> Path measurement" page. | '''(i)''' Return to the "Generic -> Path measurement" page. | ||
'''(j)''' The "Measurement" tab should | '''(j)''' The "Measurement" tab should indicate that the measurement status is either warming up or running. | ||
'''(k)''' The "Remote client status" should say "connected". If not, a button appears which can be clicked to reconnect to the remote device. Any error will be | '''(k)''' The "Remote client status" should say "connected". If not, a button appears which can be clicked to reconnect to the remote device. Any error will be displayed in a information box. | ||