Analyze connections between remote sites: Difference between revisions

m (Remco.derooy moved page Investigating network problems on remote sites to Analyze connections between remote sites: the page does not describe any information about "Investigating network problems on remote sites".)
Line 19: Line 19:


# You need two Allegro Network Multimeters (any model).
# You need two Allegro Network Multimeters (any model).
# One Multimeter (the master device) will receive traffic information from the remote Multimeter via a atandard SSL connection; the master device must be able to connect to the remote device. If a firewall is in place between both devices, an additional rule might be necessary to connect the remote device on port 443.
# One Multimeter (the master device) will receive traffic information from the remote Multimeter via a standard SSL connection; the master device must be able to connect to the remote device. If a firewall is in place between both devices, an additional rule might be necessary to connect the remote device on port 443.


== Device installation ==
== Device installation ==


# Install the master device in your network where it can see the traffic sent and receievd to the remote site. The Multimeter can be installed on a Mirror Port on a Switch which sees all the traffic, or inline between the local network and uplink to the remote site.
# Install the master device in your network where it can see the traffic sent and received to the remote site. The Multimeter can be installed on a Mirror Port of a Switch which sees all the traffic, or inline between the local network and uplink to the remote site.
# Install the device on the remote site at a network position where it sees all traffic from and to the local network. Again, this can be a Mirror Port on a Switch on the remote site, or inline between the remote network and the link to the local network.
# Install the device on the remote site at a network position where it sees all traffic from and to the local network. Again, this can be a Mirror Port of a Switch on the remote site, or inline between the remote network and the link to the local network.


== Configuration ==
== Configuration ==
Line 32: Line 32:
|}
|}


# Remote device: There are no special configuration settings necessary on the remote device. The remote device just needs to be added as a [[Multi-device settings|multi-device]].
# Remote device: First, the remote device must be added to your multi-device setup, which can be configured under [[Multi-device settings|<u>Multi device settings</u>]].
# Master device:
# Master device:
## Access the web page of the Multimeter and go to "Generic -> Path measurement".
## Access the web page of the Multimeter and go to "Generic -> Path measurement".
316

edits