IEC 60870-5-104 module

From Allegro Network Multimeter Manual
Jump to navigation Jump to search

The IEC 60870-5-104 module shows information about IEC 60870-5-104 traffic, sequence counter correctness and response times.

Overview

Values about packets, bytes, packets per second and bytes per second of IEC 60870-5-104 traffic are shown together with a graph over time. A PCAP button allows for capturing that traffic.

A sequence counter analysis is performed per Application Service Data Unit (ASDU). Several counters provide information about:

  • Sequence number repeated: For two subsequent ASDUs the sequence number was exactly the same.
  • Sequence number too high: Between two subsequent ASDUs the sequence number did not increase by 1 but with a higher value. This is an indication about a loss.
  • Sequence number too low: Between two subsequent ASDUs the sequence number did not increase by 1. The latter ASDU had a lower value.

Please note that there may be several ASDUs in one packet.

A response time calculation is performed between Act and ActCon ASDUs and its min, average and max values are shown.

Connections

All IEC 60870-5-104 connections are shown.

Following information is available:

  • IP and port of source and destination
  • Traffic counters
  • Counter about sequence numbers, loss and response times
  • All seen ASDU addresses per connection
  • All seen type IDs per connection
  • Telegram format counters
  • Commonly used cause of transmission counters
  • History graphs of traffic, sequence number analysis, response times, telegram format and cause of transmission. The graph can be switched by clicking on the small graph icon in the graph title.
  • PCAP button allow for capturing this particular connection

A live filtering with IP, names, ASDU address or type ID can be applied on the table.