IPMI BMC update: Difference between revisions
Jump to navigation
Jump to search
Access restrictions were established for this page. If you see this message, you have no access to this page.
No edit summary |
No edit summary |
||
Line 46: | Line 46: | ||
|- | |- | ||
|Allegro 1000/1200 rev 1 | |Allegro 1000/1200 rev 1 | ||
|[https://www.supermicro.com/en/support/resources/downloadcenter/firmware/MBD- | |[https://www.supermicro.com/en/support/resources/downloadcenter/firmware/MBD-X10SDV-TP8F/BMC] | ||
|- | |- | ||
|Allegro 1000/1200 rev 3 | |Allegro 1000/1200 rev 3 | ||
|[https://www.supermicro.com/de/support/resources/downloadcenter/firmware/MBD- | |[https://www.supermicro.com/de/support/resources/downloadcenter/firmware/MBD-X11SDV-4C-TP8F/BMC] | ||
|- | |- | ||
|Allegro 3000/3200 rev 1 | |Allegro 3000/3200 rev 1 | ||
|[https://www.supermicro.com/en/support/resources/downloadcenter/firmware/MBD- | |[https://www.supermicro.com/en/support/resources/downloadcenter/firmware/MBD-X10SDV-7TP8F/BMC] | ||
|- | |- | ||
|Allegro 3000/3200 rev 3 | |Allegro 3000/3200 rev 3 | ||
|[https://www.supermicro.com/de/support/resources/downloadcenter/firmware/MBD- | |[https://www.supermicro.com/de/support/resources/downloadcenter/firmware/MBD-X11SDV-16C-TP8F/BMC] | ||
|- | |- | ||
|Allegro 1300/3300/5300 rev 1 | |Allegro 1300/3300/5300 rev 1 | ||
|[https://www.supermicro.com/en/support/resources/downloadcenter/firmware/MBD- | |[https://www.supermicro.com/en/support/resources/downloadcenter/firmware/MBD-H12SSW-NT/BMC] | ||
|- | |- | ||
|Allegro 1300/3300/5300 rev 3 | |Allegro 1300/3300/5300 rev 3 | ||
|[https://www.supermicro.com/en/support/resources/downloadcenter/firmware/MBD- | |[https://www.supermicro.com/en/support/resources/downloadcenter/firmware/MBD-H12DSU-iN/BMC] | ||
|- | |- | ||
|Allegro 1500/3500/5500 rev 1 | |Allegro 1500/3500/5500 rev 1 | ||
|[https://www.supermicro.com/de/support/resources/downloadcenter/firmware/MBD- | |[https://www.supermicro.com/de/support/resources/downloadcenter/firmware/MBD-X11DPH-T/BMC] | ||
|- | |- | ||
|Allegro 1500/3500/5500 rev 2 | |Allegro 1500/3500/5500 rev 2 | ||
|https://www.supermicro.com/en/support/resources/downloadcenter/firmware/MBD-H11SSL-NC/BMC | |https://www.supermicro.com/en/support/resources/downloadcenter/firmware/MBD-H11SSL-NC/BMC | ||
|} | |} |
Revision as of 12:44, 19 December 2023
Most Allegro Network Multimeter come with a separate Management Interface (IPMI) which runs even if the system is powered off.
This "Baseboard Management controller" (BMC) can be updated by the user manually by logging into the IPMI interface and executing the update steps described below.
Known Vulnerabilities
This section lists all known vulnerabilities, affected models and solutions.
The "System ID" in the Allegro web interface "Info -> System Info" contains the model number, such as "Allegro-5300-rev2+...".
Firmware version >= 4.2 lists possible updates for the BMC at the page "Settings -> Firmware update".
List of known vulnerabilities:
- https://www.supermicro.com/en/support/security_BMC_IPMI_Oct_2023
- Related CVEs:
- CVE-2023-40289
- CVE-2023-40284
- CVE-2023-40287
- CVE-2023-40288
- CVE-2023-40290
- CVE-2023-40285
- CVE-2023-40286
- Affected Allegro models:
- 1000-rev1
- 1200-rev1
- 1000-rev3
- 1200-rev3
- 3000-rev1
- 3200-rev1
- 3000-rev3
- 3200-rev3
- x300-rev1
- x300-rev3
- x500-rev1
- x500-rev2
- Related CVEs:
Update steps
- Select your model from the following list and download the update zip file:
Model | Update download |
---|---|
Allegro 1000/1200 rev 1 | [1] |
Allegro 1000/1200 rev 3 | [2] |
Allegro 3000/3200 rev 1 | [3] |
Allegro 3000/3200 rev 3 | [4] |
Allegro 1300/3300/5300 rev 1 | [5] |
Allegro 1300/3300/5300 rev 3 | [6] |
Allegro 1500/3500/5500 rev 1 | [7] |
Allegro 1500/3500/5500 rev 2 | https://www.supermicro.com/en/support/resources/downloadcenter/firmware/MBD-H11SSL-NC/BMC |