<big>''' IPFIX settings'''</big> | <big>''' IPFIX settings'''</big> | ||
The Allegro Network Multimeter may be running as an IPFIX exporter. These settings allows configuration of reporting. When enabled, following settings are possible: | |||
* IP address: Address of IPFIX collector | |||
* Port: Corresponding port | |||
* Protocol: TCP or UDP | |||
* Update interval: Interval in seconds for sending a status update of flows | |||
* UDP resend interval: Interval in seconds for resending IPFIX templates for UDP connections | |||
* TCP reconnect timeout: When TCP connection could not be established, wait for this time period until next try to establish a connection. | |||
Individual IPFIX messages can be enabled or disabled by toggling corresponding options. See the NetFlow/IPFIX interface documentation for details about the message types. | |||
<big>''' Time settings'''</big> | <big>''' Time settings'''</big> |