Analyze connections between remote sites: Difference between revisions

no edit summary
No edit summary
Line 39: Line 39:
## Enter an descriptive name for the master device to make it easier to read the statistics.
## Enter an descriptive name for the master device to make it easier to read the statistics.
## For the remote device, enter the information described above. You can select a descriptive name for this device also.
## For the remote device, enter the information described above. You can select a descriptive name for this device also.
## Enter a maximum packet delay. This parameter defines how long the master device waits for data from the remote device until it decides whether or not a packet as been lost. Larger values requires more memory. Typical values are between 2 and 5 seconds.
## Enter a maximum packet delay. This parameter defines how long the master device waits for data from the remote device until it decides whether or not a packet has been lost. Larger values requires more memory. Typical values are between 2 and 5 seconds.
## Finally save the configuration settings.
## Finally save the configuration settings.
## At the bottom of the page a note will appear in most cases that a restart of the packet processing is necessary. Follow the link to the administration page and click on "Restart processing". Be aware that this will interrupt the network connection for a few seconds (if in Bridge mode); you will lose all previously measured data.
## At the bottom of the page a note will appear in most cases that a restart of the packet processing is necessary. Follow the link to the administration page and click on "Restart processing". Be aware that this will interrupt the network connection for a few seconds (if in Bridge mode); you will lose all previously measured data.
## Return to the "Generic -> Path measurement" page.
## Return to the "Generic -> Path measurement" page.
## The "Measurement" tab should indicate that the measurement status is either warming up or running.
## The "Measurement" tab should indicate that the measurement status is either warming up or running.
## The "Remote client status" should say "connected". If not, a button appears which can be clicked to reconnect to the remote device. Any error will be displayed in a information box.
## The "Remote client status" should say "connected". If not, a button appears which can be clicked to reconnect to the remote device. Any error will be displayed in an information box.


== Evaluation ==
== Evaluation ==
325